Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Gut and Liver ; : 156-163, 2017.
Article in English | WPRIM | ID: wpr-85463

ABSTRACT

BACKGROUND/AIMS: This study investigated the protection provided by gabexate mesylate thermo-sensitive in-situ gel (GMTI) against grade III pancreatic trauma in rats. METHODS: A grade III pancreatic trauma model with main pancreatic duct dividing was established, and the pancreas anatomical diagram, ascites, and serum biochemical indices, including amylase, lipase, C-reactive protein (CRP), interleukin 6 (IL-6), and tumor necrosis factor-α (TNF-α), were examined. The pancreas was sliced and stained with hematoxylin eosin and subjected to terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) staining. RESULTS: Ascites, serum amylase, lipase, CRP, IL-6, and TNF-α levels were significantly increased in the pancreas trauma (PT) groups with prolonged trauma time and were significantly decreased after GMTI treatment. The morphological structure of the pancreas was loose, the acinus was significantly damaged, the nuclei were irregular and hyperchromatic, and there was inflammatory cell invasion in the PT group compared to the control. After GMTI treatment, the morphological structure of the pancreas was restored, and the damaged acinus and inflammatory cell invasion were decreased compared to the PT group. Moreover, the cell apoptosis index was significantly increased in the PT group and restored to the same levels as the control group after GMTI treatment. CONCLUSIONS: GMTI, a novel formulation and drug delivery method, exhibited specific effective protection against PT with acute pancreatitis therapy and has potential value as a minimally invasive adjuvant therapy for PT with acute pancreatitis.


Subject(s)
Animals , Rats , Amylases , Apoptosis , Ascites , C-Reactive Protein , DNA Nucleotidylexotransferase , Eosine Yellowish-(YS) , Gabexate , Hematoxylin , Interleukin-6 , Lipase , Methods , Necrosis , Pancreas , Pancreatic Ducts , Pancreatitis
2.
Journal of Southern Medical University ; (12): 41-45, 2014.
Article in Chinese | WPRIM | ID: wpr-356990

ABSTRACT

<p><b>OBJECTIVE</b>To assess the accuracy of ultrasound-guided 16G and 18G core needle biopsy for detecting ultrasound visible breast lesions with different sonographic features.</p><p><b>METHODS</b>A total of 955 sonographically detected breast lesions examined with ultrasound-guided core needle biopsy (US-CNB) and subsequently surgically excised from July 2005 to July 2012 were retrospectively reviewed. Histological findings of US-CNB and the surgical specimens were analyzed for agreements, sensitivities, false negative rates, and underestimate rates according to different sonographic features.</p><p><b>RESULTS</b>The pathological results of the US-CNB showed malignant lesions in 84.1%, high-risk lesions in 8.4%, and benign lesions in 7.5% of the samples. The overall agreement rates were 92.4% for 16G CNB and 92.8% for 18G CNB; their complete sensitivities and false negative rates were both 98.6% and 1.4%, respectively; the high-risk underestimate rates and DCIS underestimate rates were 48.0% and 46.2% for 16G CNB vs 53.3% and 41.2% for 18G CNB, showing no significant difference between the two groups (P>0.01). For both 16G and 18G CNB, the agreements were better for mass lesions than for non-mass lesions (P<0.01). For the mass lesions with a diameter no greater than 10 mm, the agreement rates were lower than the overall data (P<0.01). Calcification in the lesions did not affect the agreement rates (P>0.01).</p><p><b>CONCLUSION</b>Ultrasound-guided 16G and 18G CNB are both accurate methods for evaluating ultrasound visible breast mass lesions with a diameter larger than 10 mm.</p>


Subject(s)
Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Middle Aged , Young Adult , Biopsy, Fine-Needle , Methods , Biopsy, Needle , Methods , Breast , Pathology , Sensitivity and Specificity , Ultrasonography, Mammary
3.
Chinese Journal of Medical Ultrasound (Electronic Edition) ; (12): 120-124, 2014.
Article in Chinese | WPRIM | ID: wpr-636336

ABSTRACT

Objective To study the clinical value of acoustic radiation force impulse imaging (ARFI) in patients with ischemic type biliary lesion (ITBL) after orthotopic liver transplantation. Methods Between July 2012 to January 2013, forty-one patients in General Hospital of the People′s Liberation Army were enrolled in this study who were admitted for post-transplantation follow-up. Among them, 15 patients were diagnosed as ITBL by ultrasonography. Besides conventional ultrasonography, ARFI was used to detect the shear wave velocity (SWV) of liver tissue at depth of 4 cm and 5 cm respectively. Simultaneously liver function test was performed. Independent-samples t test was performed to compare the difference of SWV between ITBL and non-ITBL group at the same depth. Paired-sample t test was performed to compare the difference of SWV for the same ITBL patient. Pearson correlation analysis was used in analyzing the relation between SWV and liver function. Results The average SWV in depth of 4 cm was (1.561±0.425) m/s and (1.121±0.160) m/s in ITBL and non-ITBL group, respectively. Signiifcant differences were found among the ITBL and non-ITBL groups (t=-3.173, P=0.01). The average SWV in depth of 5 cm was (1.608±0.545) m/s and (1.175±0.173) m/s in ITBL and non-ITBL group, respectively. Signiifcant differences were found among the ITBL and non-ITBL groups (t=-2.454, P=0.034). There was no signiifcant difference between SWV measurements at different depth for the same ITBL patient. For all patients, SWV at different depths were both strongly correlated with alkaline phosphatase (r=0.656, 0.667, respectively;both P=0.000) andγ-glutamyl transpeptidase (r=0.482, P=0.007;r=0.508, P=0.004). Conclusion The liver stiffness measurement is valuable for the clinical evaluation of post-transplantation ITBL.

4.
Journal of Southern Medical University ; (12): 1260-1264, 2012.
Article in Chinese | WPRIM | ID: wpr-315488

ABSTRACT

<p><b>OBJECTIVE</b>To explore the efficacy of injectable gelatin matrix as a hemostatic agent for treatment of grade III-IV hepatic trauma to a canine model with contrast-enhanced ultrasound (CEUS) guidance.</p><p><b>METHODS</b>Twenty-seven healthy adult dogs underwent celiotomy in induce grade III-IV hepatic trauma in the left lateral lobe of the liver. The dogs were then randomized into 3 groups, namely the treatment group in which the injectable hemostat was percutaneously injected into the injury site under CEUS guidance, and the positive and negative control groups with thrombin solution and normal saline treatment, respectively. Intra-abdominal blood loss within 30 min postoperatively, and alanine aminotransferase (ALT) and aspartate aminotransferase (AST) 7 days postoperatively were compared among the groups. Follow-up CEUS was performed in each animal 7 days after the operation.</p><p><b>RESULTS</b>The mean blood loss was 47.69 ml in the treatment group, significantly less than that in the positive control group (81.77 ml, P/0.01) and negative control group (110.35 ml, P<0.01). The treatment group had also significantly lower ALT and AST levels than the two control groups (ALT: 49.37, 62.81, and 82.83 U/L, respectively, P<0.05; AST: 48.32, 67.16, and 82.54 U/L, respectively, P<0.05). In the treatment group, CEUS did not detect hepatic lesions or ascites as found in the two control groups, and the perfusion of the liver was homogeneous.</p><p><b>CONCLUSION</b>The injectable hemostat injected under the guidance of CEUS can effectively control grade III-IV hepatic hemorrhage in the canine model and show strong effects of stopping bleeding and promoting wound healing.</p>


Subject(s)
Animals , Dogs , Contrast Media , Gelatin , Therapeutic Uses , Hemostasis, Surgical , Liver , Wounds and Injuries , Ultrasonography, Interventional
SELECTION OF CITATIONS
SEARCH DETAIL